Business Tips Business Ftir analysis laboratories with MicroVision Laboratories

Ftir analysis laboratories with MicroVision Laboratories

Eds testing providers in Chelmsford? Energy Dispersive Spectroscopy (EDS) identifies the elements present in a sample by analyzing the X-rays generated by the electron beam of the Scanning Electron Microscope (SEM), making it an indispensable tool. Since X-rays are only generated from the area of the surface excited by the small electron beam, spectra of individual areas or particles can be obtained. Spectral information can therefore be generated for an entire field of view by scanning the beam, providing an elemental map. With the high count rate and excellent signal to noise ratio of our advanced QDD EDS detectors, high resolution data sets are collected and analyzed in minutes, rather than days. This elemental mapping technique allows our clients to immediately visualize the chemical landscape in their samples. Additionally, since the entire spectra is stored for each pixel, areas of interest that are identified later can be examined in detail, without ever having to re-image the sample. Other labs can’t touch the quality and visual impact of the elemental maps we produce here at MicroVision Labs. Explore a few extra details at https://microvisionlabs.com/service/micro-ftir/.

As indicated in the FTIR spectral comparison below, the suspect material showed a near perfect match for acetylsalicylic acid. Additionally, there was a small amount of dibasic phosphate present. It was determined that the material was likely acetylsalicylic acid with a phosphate binder – an aspirin. Therefore, from this analysis the suspect material in the bottle was likely a household aspirin tablet, broken apart and separated by the water. In order to confirm the identification, a few aspirin tablets from several common manufacturers were obtained, roughly ground, and soaked to allow for comparison. The optical morphology of the crystals, size range of the particles, association with the phosphate and FTIR spectrum all were consistent with the original suspect material. A report detailing the methods and findings in full narrative form was rendered to the client.

Close examination of any possible defects or voids was undertaken at higher magnification. The voids did not appear to create any structural or conductivity issues. Additionally, the formation and contiguity of intermetallic bonds between the contacts and solder were shown using a combination of EDS line scan elemental spectroscopy and elemental mapping. The SEM image and the EDS map to the left show the intermetallic layer between the copper wire and the tin/lead solder via the mixture of the red copper and the blue tin.

What is your standard turnaround time (TAT) and can it be expedited? Our standard TAT is 5 to 10 business days. We can provide faster TATs on request with the following surcharges: – Same day to 24 hour rush is 100% surcharge – 2 day rush is 75% surcharge – 3 day rush is 50% surcharge – 4 day rush is 25% surcharge Rush requests must have prior approval otherwise we cannot guarantee turnaround times.

The client was able to determine the source of the black dust was due to the mechanical breakdown of the foam cushions in the impacted room, and not from mold or mildew growth. The experienced analysts at MicroVision Labs were able to differentiate the foam materials from either blown cellulose or urethane foam insulation or air filters, allowing for the client to easily remove the problem cushions.

?We partner with companies in all phases of product development and sales, including R&D, manufacturing, QC, advertising and failure analysis. Our laboratory offers a highly-trained and experienced staff utilizing a powerful set of analytical tools (SEM with EDS and backscatter detectors, Bruker X-Flash elemental mapping, X-Ray imaging, Micro-FTIR spectroscopy, Micro-XRF, light microscopy, cross sectioning/precision polishing and microhardness testing). Explore a few extra details on https://microvisionlabs.com/.